Questions & Answers

EVO-ALL + CM6200 + 2W4500 Problem in 2011 Hyundai Tucson - regular key

+1 vote
I install a 2w4500 with CM6200 module and EVO-ALL using 'data to data' connection. At the beginning is working perfect but after I try a few time, I can lock the door but can't unlock the door, also the LCD remote control show unlock the door automatic after 5 sec. but door is no response . Remote starter is not working and error diagnodtic flash 5 times means 'foot brake on' EVO-ALL hardware is 6 and firmware is 4.18. Any solution?
posté Jan 14, 2014 dans la catégorie Hyundai par Raymond Yim (300 points)

1 Réponse

0 votes
Hi Raymond,

 
If using datalink, make sure to program Fortin Protocol in the CM6200. If you are still having issues after that.  I recommend not using datalink and connecting Lock/Unlock, Brake, Tach etc, from EVO to remote start directly. It will be easier for you to test anything afterward if the problem is not solved.
répondu Jan 15, 2014 par Robert T (301,890 points)
...